Fiberglass alkali-resistance dipped mesh
They are made of yarn or roving by means of leno or plain weave.The
diameter of elementary glass fibres varies between 9 and 17micron.
Mesh fabrics combined with specially designed mesh surface
treatments can be used in a wide range of applications,but are
mainly used in construction industry. Surface treatments based on
styrene-butadiene ensure alkali resistance and increase the
mechanical durability that is required by the construction
industry. In addition,other surface treatments based on PVAc ,PVC
or styrene-acrylate are used for different.
Name of application
Used type of mesh fabricsExternal Thermo Insulating Composite
System(ETICS/EIFS)
AL68, AL120, AL130, AL145, AL150, AL159, AL160, AL187, AL217,
AL330, AL343, AL391, AL476, AL540, AL600, AL697Finishing components
manufacturing
AL60, AL76, AL100, AL120, AL145, AL159, AL160External and internal
plaster reinforcement
AL60, AL65, AL100, AL110, AL120, AL130, AL159, AL160, AL343,
AL540Style of reinforced lightweight construction boards
AL90, AL100Marble slab reinforcement
AL63, AL70, AL80(with A105 treatment)Mosaic carrier
AL130, AL145, AL159, AL160, AL201Electrical heating mats
AL90, AL130Floor reinforcement
AL110, AL120, AL130, AL138, AL217Asphalt and other insulator
reinforcement
AL60, AL70, AL110, AP60, AP70, AP82applications:
Example of marking
Example:AL68 A101
AL68 ype of fabrics (AL-mesh)with finished fabrics weight in
g/m2(68g/m2),A lkali resitance,L eno, (P lain).
A 101-alkali resistant surface treatment
A 105-surface treatment with soft or hard resin
Lits of applications by types of mesh fabrics.Mesh fabrics are
wound on paper tubes with inner diameters of 50.8 ,76 or 152mm.The
quantity of fabric wound on the tube is determined by customer
requirements and varies from just 50 meters to the thousands of
meters needed for a machine processing.Mesh fabrics are offered in
widths of between 10 cm and 180 cm in addition to the standard 100
cm.
Storage:
Store rolls in a cool, dry location;Store away from direct contact
with the ground or concrete;Store out of direct sunlight;Protect
rolls from weather and other damage;Store individual rolls or roll
cased on end!!External Thermal Insulating Composite Systems(ETICS)
External Insulation Finish Systems (EIFS)
ETICS /EIFS composition
1.Wall surface
2.Adhesive
3.Thermo insulating boards
4 .Reinforcing coat
5. Reinforcing mesh fabrics
6. Facade render
ETICS/EIFS are not only used to renew old panel buildings and
houses. They also play an integral role in new housing projects.
The first thermo image shows a thermo leak through a building skin
before renovation. The second thermo image demonstrates the leak
reduction as a result of ETICS/EIFS.Fiberglass roofing waterproof
scrim
As there is almost no strength in waterproof medium (bitumen)
itself,the waterproof system is easy to crack and leak due to
temperature change,sunshine and wind ,etc. When put the fiberglass
scrim in the system, it can strengthen the ability to resist this
influence because of its properties of alkali-resistance and high
tensile strength.This will bring people a comfortable space and
convenience life.
Marble slab reinforcement/mosaic carrier External and internal
plaster reinforcement
Examples of use
1.Walls with channels for electrical wires and joints of two
different materials(wall made of lightweight material - metal beam)
2.Two different materials joint (wall made of lightweight
material-concrete wall)
3.Modern construction technology
Application procedure
1.Surface treatment
2.Plaster application
3.Reinforcing mesh lay down
4.Mesh adjustment
5.Mesh embedding
6.Finishes wall with reinforced plaster
Electrical/steam floor heating mats
Installation procedure
1.Electrical floor heating mat. The floor must be sufficiently
cleaned before the heating mat is laid-down.2.The heating mat is
unfolded on the floor.The heating mat should be laid down without
any creases and then secured so as to prevent it slipping. When
laid down direction is changed ,cut the glass fibre mesh belt. Be
very careful not to cut heating wire.
3.Detail of installed heating mat.Reinforced lightweight
construction boards Construction panel structure
1-Reinforced panel
2-Reinforcing mass
3-Reinforcing glass fibre mesh fabrics
4-Surface of finished panel
Bathroom buliding procedure
1.Preparation of structural modules
2.Bath with wall
3.Bathroom before final completion
standard packaging

